<?xml version="1.0" encoding="UTF-8"?><!DOCTYPE ArticleSet PUBLIC "-//NLM//DTD PubMed 2.7//EN" "https://dtd.nlm.nih.gov/ncbi/pubmed/in/PubMed.dtd">
<ArticleSet>
		<Article>
		<Journal>
			<PublisherName>Journal of Theoretical and Applied Physics (JTAP)</PublisherName>
			<JournalTitle>Industrial application of apodized gas sensor for on-line and in situ measurement of CO and CO2 concentration</JournalTitle>
			<Issn></Issn>
			<Volume>Volume 14 (2020)</Volume>
			<Issue>Issue 4, August 2020</Issue>
			<PubDate PubStatus="epublish">
                <Year>2023</Year>
                <Month>11</Month>
                <Day>17</Day>
			</PubDate>
		</Journal>
		<ArticleTitle>Industrial application of apodized gas sensor for on-line and in situ measurement of CO and CO2 concentration</ArticleTitle>
		<VernacularTitle></VernacularTitle>
		<FirstPage></FirstPage>
		<LastPage></LastPage>
		<ELocationID EIdType="doi">10.1007/s40094-020-00396-z</ELocationID>
		<Language>EN</Language>
		<AuthorList>
            			<Author>
                				<FirstName>Alireza</FirstName>
				<LastName>Khorsandi</LastName>
				<Affiliation>Department of Physics, University of Isfahan, Isfahan 81746‑73441, Iran</Affiliation>
				<Identifier Source="ORCID">0000-0002-9086-718X</Identifier>
			</Author>
            			<Author>
                				<FirstName>Saeed</FirstName>
				<LastName>Ghavami Sabouri</LastName>
				<Affiliation>Department of Physics, University of Isfahan, Isfahan 81746‑73441, Iran</Affiliation>
				<Identifier Source="ORCID">0000-0002-6200-4459</Identifier>
			</Author>
            		</AuthorList>
		<PublicationType>Journal Article</PublicationType>
		<History>
			<PubDate PubStatus="received">
				<Year>2023</Year>
				<Month>11</Month>
				<Day>17</Day>
			</PubDate>
		</History>
		<Abstract>AbstractThe performance of an apodized gas sensor is demonstrated through simultaneous detection of CO and CO2 absorption lines around 1.57 µm in the recuperator channel of a gas-fired industrial furnace at Shahid Montazeri power plant (SMPP) industry. This led to the concentration measurement of targeted molecules as less than ~ 1% and 9.5%, respectively, at atmospheric pressure and 350 °C, indicating close consistency with the reference data reported by SMPP. A minimum detectable absorption of ~ 0.4 × 10−3, corresponding to a detection sensitivity of ~ 4.8 × 10−9 cm−1 Hz−1/2 is measured in this application.</Abstract>
		<ObjectList>
            			<Object Type="keyword">
				<Param Name="value">Apodized gas sensor</Param>
			</Object>
						<Object Type="keyword">
				<Param Name="value">Tunable diode laser</Param>
			</Object>
						<Object Type="keyword">
				<Param Name="value">Wavelength modulation spectroscopy</Param>
			</Object>
					</ObjectList>
	</Article>
	</ArticleSet>