<?xml version="1.0" encoding="UTF-8"?><!DOCTYPE ArticleSet PUBLIC "-//NLM//DTD PubMed 2.7//EN" "https://dtd.nlm.nih.gov/ncbi/pubmed/in/PubMed.dtd">
<ArticleSet>
		<Article>
		<Journal>
			<PublisherName>International Journal of Nano Dimension (Int. J. Nano Dimens.)</PublisherName>
			<JournalTitle>A simulation study on the performance of various label-free electronic biosensors</JournalTitle>
			<Issn></Issn>
			<Volume>Volume 2 (2011)</Volume>
			<Issue>Issue 1, August 2011, ICECCA 2010, WCN 2011</Issue>
			<PubDate PubStatus="epublish">
                <Year>2024</Year>
                <Month>03</Month>
                <Day>01</Day>
			</PubDate>
		</Journal>
		<ArticleTitle>A simulation study on the performance of various label-free electronic biosensors</ArticleTitle>
		<VernacularTitle></VernacularTitle>
		<FirstPage></FirstPage>
		<LastPage></LastPage>
		<ELocationID EIdType="doi">10.7508/ijnd.2011.01.006</ELocationID>
		<Language>EN</Language>
		<AuthorList>
            			<Author>
                				<FirstName>K.</FirstName>
				<LastName>Talukdar</LastName>
				<Affiliation>Department of Physics, NIT-Durgapur-713209, West Bengal, India.</Affiliation>
				<Identifier Source="ORCID"></Identifier>
			</Author>
            			<Author>
                				<FirstName>A.</FirstName>
				<LastName>K. Mitra</LastName>
				<Affiliation>Department of Physics, NIT Durgapur, West Bengal, India.</Affiliation>
				<Identifier Source="ORCID"></Identifier>
			</Author>
            		</AuthorList>
		<PublicationType>Journal Article</PublicationType>
		<History>
			<PubDate PubStatus="received">
				<Year>2024</Year>
				<Month>03</Month>
				<Day>01</Day>
			</PubDate>
		</History>
		<Abstract>The efficient detection of charged biomolecules by biosensor with appropriate semiconducting nanomaterials and with optimum device geometry has caught tremendous research interest in the present decade. Here, the performance of various label-free electronic biosensors to detect bio-molecules is investigated by simulation technique. Silicon nanowire sensor, nanosphere sensor and double gate field effect transistor (DGFET) sensor with different device parameters are reported here and their performances are compared. For the three types of sensors, radius of the nanowire, radius of the nanosphere and the silicon body thickness for the DGFET are varied to compare their selectivity, sensitivity, settling time etc. The result of adjustment of the flow of the fluid is also investigated by simulation.</Abstract>
		<ObjectList>
            			<Object Type="keyword">
				<Param Name="value">Selectivity</Param>
			</Object>
						<Object Type="keyword">
				<Param Name="value">Simulation</Param>
			</Object>
						<Object Type="keyword">
				<Param Name="value">Sensitivity</Param>
			</Object>
						<Object Type="keyword">
				<Param Name="value">Biosensor</Param>
			</Object>
						<Object Type="keyword">
				<Param Name="value">Label-free</Param>
			</Object>
					</ObjectList>
	</Article>
	</ArticleSet>