		<Journal>
			<PublisherName>Majlesi Journal of Electrical Engineering</PublisherName>
			<JournalTitle>Design of Novel Approach to Mitigate Voltage Sag Caused by Starting an Induction Motor Using Dynamic Voltage Restorer</JournalTitle>
			<Issn></Issn>
			<Volume>Volume 10 (2016)</Volume>
			<Issue>Issue 4, December 2016</Issue>
			<PubDate PubStatus="epublish">
                <Year>2024</Year>
                <Month>02</Month>
                <Day>20</Day>
			</PubDate>
		</Journal>
		<ArticleTitle>Design of Novel Approach to Mitigate Voltage Sag Caused by Starting an Induction Motor Using Dynamic Voltage Restorer</ArticleTitle>
		<VernacularTitle></VernacularTitle>
		<FirstPage></FirstPage>
		<LastPage></LastPage>
		<ELocationID EIdType="doi"></ELocationID>
		<Language>EN</Language>
		<AuthorList>
            			<Author>
                				<FirstName>Mojtaba</FirstName>
				<LastName>Kheibar</LastName>
				<Affiliation>Shahid Chamran University of Ahvaz</Affiliation>
				<Identifier Source="ORCID"></Identifier>
			</Author>
            			<Author>
                				<FirstName>M.</FirstName>
				<LastName>Joorabian</LastName>
				<Affiliation>Shahid Chamran University, Ahvaz, Iran</Affiliation>
				<Identifier Source="ORCID"></Identifier>
			</Author>
            			<Author>
                				<FirstName>E.</FirstName>
				<LastName>Noori</LastName>
				<Affiliation>Ahvaz Electricity Distribution Company, Ahvaz, Iran</Affiliation>
				<Identifier Source="ORCID"></Identifier>
			</Author>
            			<Author>
                				<FirstName>R.</FirstName>
				<LastName>Karambeigi</LastName>
				<Affiliation>Ahvaz Electricity Distribution Company, Ahvaz, Iran</Affiliation>
				<Identifier Source="ORCID"></Identifier>
			</Author>
            		</AuthorList>
		<PublicationType>Journal Article</PublicationType>
		<History>
			<PubDate PubStatus="received">
				<Year>2024</Year>
				<Month>02</Month>
				<Day>20</Day>
			</PubDate>
		</History>
		<Abstract>In this paper a new control strategy for dynamic voltage restorer (DVR) is presented to compensate effectively voltage sags. In this strategy, load and supply voltage magnitude and angle are estimated by least error square in short time. Advantage of this method is reducing noise, distortion and harmonic on estimation parameters. Accordingly, these parameters are controlled for each phase separately. Also, it should be noted that due to angle estimation by LES filters, control system does not require phase-locked Loop and this issue causes increase in speed of control system response. In addition, a P+Resonant and Posicast controller are used to eliminate the steady-state error and improve transient response in DVR, respectively. The proposed control system is simulated, using PSCAD/EMTDC software by induction motors starting is connected to 13 bus IEEE standard network. Finally, the simulation results prove that the proposed control scheme performs satisfactorily under sudden changes of load.</Abstract>
		<ObjectList>
            			<Object Type="keyword">
				<Param Name="value">Voltage Sag</Param>
			</Object>
						<Object Type="keyword">
				<Param Name="value">Dynamic Voltage Restorer</Param>
			</Object>
						<Object Type="keyword">
				<Param Name="value">Least error squares filters</Param>
			</Object>
						<Object Type="keyword">
				<Param Name="value">Control system. Power Quality</Param>
			</Object>